Differences between CYPE's acoustic analysis applications

The following table shows the differences between CYPE's acoustic analysis applications (CYPESOUND and AcouBAT by CYPE):

CYPESOUND AcouBAT by CYPE
Analysis method
Analysis rulesUNE-EN 12354-1:2000
UNE-EN 12354-2:2001
UNE-EN 12354-3:2001
UNE-EN 12354-5:2009
UNE-EN 12354-6:2004
UNE-EN ISO 12354-1:2018
UNE-EN ISO 12354-2:2018
UNE-EN ISO 12354-3:2018

UNE-EN 12354-5:2009
UNE-EN 12354-6:2004
Analysis engineCYPEAcouBAT (CSTB)
Third-octave band analysis
(detailed model)
NO1YES
Available analyses
Analysis of airborne sound insulation
and impact
YESYES
Sound absorption analysisYESYES
Analysis of the sound pressure level
produced by the building equipment
YESYES
Analysis of noise transmitted through
the air-conditioning system
YESNO
Analysis of airborne noise transmission
through aerators or other small building elements
NOYES
Open BIM Integration
Access to the projects of the
BIMserver.center platform
YESYES
Reading the geometric modelYESYES
Reading noise sourcesYESYES
BIM model updatingYESYES
Exporting results and reportsYESYES
Defining requirements
Selecting global acoustic indicesYESYES
Editing airborne and impact sound insulation limit valuesYESYES
Editing the sound pressure limit values produced by building equipmentNOYES
Predefined and editable regulationsNOYES2
Acoustic characterisation
Defining acoustic values in one-third octave bandsNO3YES
CSTB acoustic testing databaseNOYES
Database from CYPE Cost DatabaseNONO
Predicting the sound insulation of construction systemsYESNO
Analysis model
Direct editing of the entry data from the analysis engineYESYES
Defining the form factor of the façade according to the UNE-EN ISO 12354-3 standardNOYES
Results analysis
Dynamic histogramNOYES
Detailed analysis of each transmission path in third octave bandsNOYES
3D viewing of the elements involved in each transmission pathNOYES
Exporting results in XLS formatNOYES
Justification report of resultsYESYES
Materials reportNOYES
DrawingsNONO
1 The simplified model is used. The simplified model analyses the building characteristics as a global index based on the global indices of the elements involved.
2 Acoustic requirements are included for Spain (CTE DB HR), France (NRA), Portugal (RRAE), Italy (D.C.P.M. of 5 December 1997) and Brazil (NBR 15575).
3 Global acoustic indices only.