2022.b

The walls of the floor slabs with elevation changes must be situated on the elevation change axis

The following error appears in IFC Builder on the closing of elevation changes entered between two floor slabs at different levels: The walls of the floor slabs with elevation changes must be situated on the elevation change axis. A closing of elevation change cannot be entered in a location that is not previously interpreted by […]

The walls of the floor slabs with elevation changes must be situated on the elevation change axis Read More »

The selected file does not include the description of the space limits, hence it cannot be imported

The following warning may appear when importing BIM models into CYPE thermal and acoustic study programs, such as CYPETHERM EPlus: The selected file does not include the description of the space limits, hence it cannot be imported. To fix the error, the Open BIM Analytical Model file shall be selected as the initiator instead of

The selected file does not include the description of the space limits, hence it cannot be imported Read More »

The number of panels that are connected in series in each branch of the MPPT follower must be the same

In CYPELEC PV Systems, users may see the following error after analysing the installation: The number of panels that are connected in series in each branch of the MPPT follower must be the same. To correct the error, the same number of PV panels must be entered in each of the branches that make up

The number of panels that are connected in series in each branch of the MPPT follower must be the same Read More »