One of the elements of the continuous beam forms an angle greater than 80 with the horizontal plane

CYPE 3D may display the following error: One of the elements of the continuous beam forms an angle greater than 80 with the horizontal plane. The problem can be found in the "Analysis" menu, selecting "Show/Hide incidents": The problem is caused by an element that is defined as a "Beam" but whose directrix is close […]

One of the elements of the continuous beam forms an angle greater than 80 with the horizontal plane Read More »

The element must be vertical, with its local x axis in the ascending direction

CYPE 3D may display the following error: The element must be vertical, with its local x axis in the ascending direction. The problem can be found in the "Analysis" menu, selecting "Show/Hide incidents": The problem originates from an element that is defined as a "Column" but is positioned horizontally (its local x axis has no

The element must be vertical, with its local x axis in the ascending direction Read More »

How to convert jobs from classic programs to Open BIM programs (BIMserver.center)

This procedure is used for the following: Converting a job from Embedded retaining walls to a job from StruBIM Embedded Walls. Converting a job from Deep Beams to a job from StruBIM Deep Beams. The step-by-step procedure is detailed below: 1. Make a copy of the job to be converted from the classic program, and

How to convert jobs from classic programs to Open BIM programs (BIMserver.center) Read More »